Evaluation of structural health monitoring at the Edgardo Rebagliati Martins hospital with a limited number of accelerometers in the city of Lima
DOI:
https://doi.org/10.21754/tecnia.v32i2.1422Keywords:
Structural Health Monitoring, Capacity curve, Wavelet transform, Arrangements of sensors, InterpolationAbstract
Structural Health Monitoring (SHM) allows assessing the structural damage in observed buildings through different methodologies, which observe changes in the structural behavior immediately after an earthquake. Some methodologies assess the structural damage by observing its global capacity curve obtained through the displacement and acceleration in all stories, calculated using wavelet transform and double integration process. Due to limited resources, some floors are instrumented, and non-instrumented stories response could be estimated by additional procedures, for instance the spline shape function. In this paper, different arrangements of sensors in the Edgardo Rebagliati Martins Hospital (HERM) are evaluated to find the best possible configuration to estimate the global capacity curve and the interstories capacity curves. A 14-story building in the HERM is analyzed, and the optimal arrangement to estimate the capacity curve for each interstory capacity curve was using 7 sensors, and 4 sensors were sufficient to estimate the global capacity curve of this building.
Downloads
References
[2] M. P. Limongelli, “The interpolation damage detection method for frames under seismic excitation,” J. Sound Vib., vol. 330, no. 22, pp. 5474–5489, 2011, doi: 10.1016/j.jsv.2011.06.012.
[3] K. Kusunoki, D. Hinata, Y. Hattori, and A. Tasai, “A new method for evaluating the real‐time residual seismic capacity of existing structures using accelerometers: Structures with multiple degrees of freedom,” Japan Archit. Rev., vol. 1, no. 1, pp. 77–86, 2018, doi: 10.1002/2475-8876.1010.
[4] H. Pan and K. Kusunoki, “Capacity Curve Estimation for High-Rise Buildings Using Limited Number of Sensors,” J. Earthq. Eng., vol. 2469, 2019, doi: 10.1080/13632469.2019.1592792.
[5] M. Diaz, P. Gibu, L. Estacio, and R. Proano, “Implementation of building monitoring network in Peru under SATREPS project,” J. Disaster Res., vol. 9, no. 6, pp. 1001–1007, 2014, doi: 10.20965/jdr.2014.p1001.
[6] M. P. Limongelli, “Optimal location of sensors for reconstruction of seismic responses through spline function interpolation,” Earthq. Eng. Struct. Dyn., vol. 32, no. 7, pp. 1055–1074, 2003, doi: 10.1002/eqe.262.
[7] K. Kusunoki, A. Elgamal, M. Teshigawara, and J. P. Conte, “Evaluation of Structural Condition Using Wavelet Transforms,” in 14WCEE - 14th World Conference on Earthquake Engineering, Beijing, China, 2008.
[8] Y. Nakamura, “On the H/V spectrum”, in 14WCEE - 14th World Conference on Earthquake Engineering, Beijing, China, 2008.
[9] Z. Aguilar, M. Roncal, and R. Piedra, “Probabilistic Seismic Hazard Assessment in the Peruvian Territory in 16WCEE - 16th World Conference on Earthquake Engineering, Santiago, Chile, 2017.
[10] C. Fajardo, “Structural Evaluation of one of the Edgardo Rebagliati Martins Hospital buildings using the Capacity Spectrum Method” Eng. Thesis, Sch. of Civil Eng., National University of Engineering, Lima, Peru, 2012.
[11] Ministry of construction housing and sanitation., “Technical Standard of Building E.030: Earthquake-resistant design’” Peru, 2019.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 TECNIA