Modeling, analysis and seismic design of structures using energy dissipators SLB
DOI:
https://doi.org/10.21754/tecnia.v29i2.713Keywords:
Shear Link, precast structures, energy dissipators, seismic retrofit, hysteretic behaviourAbstract
This paper initially describes aspects of the modeling of structures equipped with energy dissipators Shear Link Bozzo (SLB) and develops two iterative design procedures to select these devices. This methodology is applied to a precast 5-story reinforced concrete building. The SLB energy dissipation devices are initially stiff, but ductile with a range of yielding forces from 36 kN to 900 kN characterized by 52 + 52 standard devices. Moreover, these devices can be combined in parallel giving a very wide range of possibilities for selection and corresponding structural response. Therefore, to simplify its automatic selection, this article presents two procedures: (1) direct iteration and (2) inverse or fixed force iteration. Both procedures were implemented in an automatic application or “plugin” for the ETABS program that automates its selection for a specific structural system or architectural configuration of these elements. Using these devices, the energy introduced by an earthquake into the structure can be dissipated, protecting other structural elements that suffer damage. The SLB energy dissipation devices are affordable to get a significant performance improvement in the overall structural response. This work presents a five-story precast reinforced concrete building frame, called SLB Building, that provides 4 departments per level all with a diaphanous interior floor. The building is made up of 11 columns with a constant 40x40cm section and all its beams have hinges at the ends. This building was equipped with 120 small SLB devices showing its performance for the maximum earthquake of Peruvian seismic code without ductility reduction (R = 1) by means of nonlinear time history with ten seismic records compatible with the S1 soil spectrum. In this structure, all seismic energy dissipation was concentrated in these devices so there would be no structural damage. In addition, the levels of non-structural damage were controlled with initial stiffness of these devices since lateral displacements were reduced to levels below the Peruvian seismic code (or even immediate occupancy for devices greater than those provided in this example). At the same time, the levels of acceleration decrease in height to only 0.3g and the base shear coefficient is reduced from almost 1.2 to only 0.12-0.2 (this means an R factor between 6 and 10 without structural damage).
Downloads
References
[1]Franchioni G 2001 Experimental investigations on semi-active and passive systems for seismic risk mitigation, ISMES Report No. 7.
[2]Cahis X, Bozzo LyTorres LL 1998 Experimental studies of various innovative energy dissipation devices, Proceedings of the Eleventh European Conference on Earthquake Engineering, Paris
[3]Bozzo L, Barbat AH 1999 Diseño sismorresistente de edificios. Técnicas convencionales y avanzadas. Barcelona: Editorial Reverte.
[4]CSI2015 ETABS Manual. Computers and Structures, Inc., Berkeley, CA.
[5]BozzoL,et al.2019 Manual de procedimiento para el diseño con SLB (in Spanish).
[6]Nuzzo I, LosannoD, Serino G,and Bozzo L2015A Seismic-resistant Precast r.c. System equipped with Shear Link Dissipatorsfor Residential Buildings, International Journal of Civil and Structural Engineering, IJCSE Vol. 2:Issue 1
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2019 TECNIA
This work is licensed under a Creative Commons Attribution 4.0 International License.