Pseudodynamic test of seismic isolator prototype with U-shaped dampers
DOI:
https://doi.org/10.21754/tecnia.v35i2.2502Palabras clave:
Pseudodynamic test, On-line control, Experimental technique, Control algorithm, Seismic isolatorResumen
The pseudodynamic testing technique combines numerical step-by-step integration with an experimental displacement-based control system to explore the seismic response of structures. Although this method has undergone significant development and has proven to be reliable and effective, its implementation in structural laboratories across Peru remains limited. To help bridge this gap, the present study applies a conventional pseudodynamic test using the control, loading, and data acquisition systems available at the Laboratory of Structures of the Japan-Peru Center for Earthquake Engineering Research and Disaster Mitigation (CISMID). The aim is to assess the performance of the control algorithm through two tests conducted on a seismic isolator prototype that incorporates U-shaped dampers. The specimen is loaded axially to simulate the tributary area of a two-story structure and is subjected to two levels of seismic input derived from the 1974 Lima earthquake record. A comparative analysis is carried out between experimental and numerical responses. The findings reveal effective displacement control and a reasonable correlation between experimental data and numerical simulations.
Descargas
Citas
[1] D. P. McCrumB, M. S. Williams, “An overview of seismic hybrid testing of engineering structures,” Engineering Structures, vol. 118, pp. 240-261, 2016, doi: 10.1016/j.engstruct
.2016.03.039
[2] P. Mortazavi, X. Huang, O. Kwon, and C. Christopoulos, “An overview of the University of Toronto (UT-SIM) Framework and its Application to the Performance Assessment of Structures,” in Proc. 7th International Conference on Advances in Experimental Structural Engineering, Pavia, 2020. [Online]. Available: https://www.researchgate.net/publication/327405277_An_Overview_of_the_University_of_Toronto_Simulation_UT-SIM_Framework_and_its_Application_to_the_Performance_Assessment_of_Structures
[3] H. Kakoty, C. Kolay, S. Raj, and K. Kar, “Real-time hybrid simulation in the Pseudo-dynamic testing facility at the Indian Institute of Technology Kanpur,” Current Science, vol. 125, no. 6, pp. 685-691, 2023, doi: 10.18520/cs/v125/i6/685-691
[4] C. Del Vecchio, M. Di Ludovico, A. Fiorillo, G. Verderame, A. Prota, G. Manfredi, and E. Cosenza, “The Pseudo-dynamic testing facility at UNINA: Preliminary Test on a RC Frame,” Italian Concrete Conference, 2020, doi: 10.1007/978-3-031-37955-0_43
[5] S. Benedetto, A. Francavilla, M. Latour, G. Cavallaro, V. Piluso, and G. Rizzano, “Pseudo-dynamic testing of a full-scale two-storey steel building with RBS connections,” Engineering Structures, vol. 212, pp. 110494, 2020, doi: 10.1016/j.engstruct
.2020.110494
[6] H. Mishra, A. Igarashi, D. Ji, and H. Matsushima, “Pseudo-dynamic testing for seismic performance assessment of buildings with seismic isolation system using scrap tire rubber pad isolators,” Civil Engineering and Architecture, vol. 8, no. 1, pp. 73-88, 2014, doi: 10.17265/1934-7359/2014.01.009
[7] K. Takanashi, and M. Nakashima, “Japanese activities on On-line testing”, Engineering Mechanics, vol. 113, pp. 1014-1032, 1987, doi: 10.1061/(ASCE)0733-9399(1987)113:7(1014)
[8] H. Scaletti, V. Chariarse, C. Cuadra, and G. Cuadros, “Pseudo dynamic tests of confined masonry buildings,” in Proc. 10th World Conference on Earthquake Engineering. Rotterdam, 1992. [Online]. Available: https://www.iitk.ac.in/nicee/wcee/article/10_vol6_3493.pdf
[9] G. Cuadros, “Estudio de modelos de albañilería confinada,” Undergradute Thesis, Faculty of Civil Engineering, National University of Engineering, Lima, 1994. [Online]. Available: http://hdl.handle.net/20.500.14076/20219
[10] C. Chunga, “Desarrollo de software para el control de actuadores en línea en ensayos de estructuras a escala natural,” Undergradute Thesis, Faculty of Civil Engineering, National University of Engineering, Lima, 2001. [Online]. Available: http://hdl.handle.net/20.500.14076/20357
[11] S. Mahin, and M. Williams, “Computer controlled seismic performance testing,” in Proc. Second ASCE-EMD Specially Conference on Dynamic Response of Structures, Atlanta, 1981.
[12] P. S. Shing, and S. Mahin, “Pseudodynamic test method for seismic peformance evaluation: Theory and Implementation,” College of Engineering at University of California, Technical Report, UCB/EERC-84/01, Jan. 1984. [Online]. Available: https://mechs.designsafe-ci.org/media/filer_public/92/82/9282cdb0-3886-4329-8fad-f9ea78563950/2_shing-mahin_pseudodynamictestmethod4seismicperformevaluation-theoryimplementation.pdf
[13] C. Zavala, “A study on substructuring hybrid simulation for flexible steel framed structures,” PhD thesis, Graduate School of Engineering, University of Tokyo, Tokyo, 1994. [Online]. Available: https://dl.ndl.go.jp/pid/3115258/1/1
[14] R. Reyna, C. Zavala, E. Flores, J. Morales, L. Nuñez, Y. Taipicuri, and D. Velasquez, “Desarrollo de un prototipo de aislamiento sísmico de bajo costo (ABC) con disipación de energía mejorada,” Vice-rectorate for Research at The National University of Engineering, Technical Report, FIC-FI-13-2020, 2021.
[15] R. Reyna, D. Velasquez, J. Chavez, and C. Zavala, “Experimental Study of Low-Cost Base Isolation prototype (ABC) with enhanced energy dissipation,” in Proc. 18th World Conference on Earthquake Engineering, Milan, 2024.
[16] Ministerio de Vivienda, Construcción y Saneamiento. RM-030-2019-Vivienda Norma Técnica E.031 “Aislamiento Sísmico”. [Online]. Available: https://www.gob.pe/institucion/sencico/informes-publicaciones/887225-normas-del-reglamento-nacional-de-edificaciones-rne
[17] C. Zavala, T. Kaminosono, “Construction Monitoring and Improvement Techniques for Masonry Housing,” CISMID-FIC-National University of Engineering, Technical report, 2003.
[18] Ministerio de Vivienda, Construcción y Saneamiento. RM-355-2018-Vivienda Norma Técnica E.030 “Diseño Sismorresistente”. [Online]. Available: https://www.gob.pe/institucion/sencico/informes-publicaciones/887225-normas-del-reglamento-nacional-de-edificaciones-rne
Descargas
Publicado
Cómo citar
Número
Sección
Licencia
Derechos de autor 2025 TECNIA

Esta obra está bajo una licencia internacional Creative Commons Atribución 4.0.
Los artículos publicados por TECNIA pueden ser compartidos a través de la licencia pública internacional Creative Commons: CC BY 4.0. Permisos lejos de este alcance pueden ser consultados a través del correo tecnia@uni.edu.pe